County of Escambia Quote
Title: Evaporator Pilot Study
Deadline: 11/1/2021 3:00 PM (UTC-06:00) Central Time (US & Canada)
Status: In Review
Quote Number: WS-EQ-2022-1
Description:
Introduction
The Escambia County Waste Services Department (ECWSD) is
seeking costs for rental of an evaporation system. ECWSD is seeking to perform an up to 3-month
pilot study in which the evaporator will be utilized in a stormwater pond
located at Perdido Landfill.
Scope of Work
ECWSD is seeking a land-based skid or trailer evaporator
system complete with PLC control systems.
Control systems should be able to manage both pump and evaporator start
up in addition to monitoring wind direction, wind high speed shut down, wind
low speed start-up, loss of pressure, data logging as well as runtime
totalizers. The evaporator unit should
also be able to easily adjust direction and angle in order to optimize plume
control and evaporation efficiency. There
is no power supply in the area of the stormwater pond; therefore, ECWSD will be
responsible for renting a generator based on the specs provided by the selected
evaporator rental company.
ECWSD goal is to select and rent an evaporator unit capable
of up to 45,000 gallons per day at a pump rate of at least 150 gallons per
minute, understanding that evaporation rates will vary based on weather conditions. Any maintenance or replacement parts above
and beyond the normal daily operation should be included during the up to 3-month
rental.
Documents:
Documents as of 10/20/2021 |
---|
Evaporator SOW.docx |
Addition 1
Posted: 11/8/2021
Type of Addition: In Review
Posted: 11/8/2021
Type of Addition: In Review