Arlington County Government Sealed Solicitation

Title: 23-DPR-RFI-632 Information Related to Prefabricated Structures

Deadline: 6/9/2023 1:00 PM   (UTC-05:00) Eastern Time (US & Canada)

Status:

Solicitation Number: 23-DPR-RFI-632

Description: The County is seeking information from Respondents who have experience and abilities in providing goods and services associated with commercial-grade prefabricated structures, including design, cost estimating, permitting, fabrication, delivery (lead time), and installation. Prefabricated structures include but are not limited to, restrooms, picnic shelters, shade structures, gazebos, trellis, dugouts, bridges, storage sheds, and kiosks.


Documents:

Documents as of 5/10/2023
23-DPR-RFI-632 Prefabricated Structures.pdf
Addition 1

Posted: 6/12/2023

Type of Addition: No Action

Question 1

Posted: 5/19/2023

Question: 1) For the precast concrete restrooms and dugouts are there preferences for the exterior appearance? Smooth stucco finish? Brick finish? 2) Any size preferences, how many stalls need to be included or just small with one men's and one women's restrooms? 3) What is the requested size on the storage sheds, are these precast concrete?

Response: Q1. For the precast concrete restrooms and dugouts are there preferences for the exterior appearance? Smooth stucco finish? Brick finish? Answer: No, this depends on the project. Q2. Any size preferences, how many stalls need to be included or just small with one men's and one women's restrooms? Answer: Unless otherwise specified, restroom stalls shall be unisex and ADA-compliant, with room for changing tables. Q3. What is the requested size on the storage sheds, are these precast concrete? Answer: There is no requested size. The size of the storage sheds will vary from project to project. They may be precast concrete, although other materials may be acceptable.

Posted: 6/12/2023

Type of Addition: No Action

Posted: 5/19/2023

Question: 1) For the precast concrete restrooms and dugouts are there preferences for the exterior appearance? Smooth stucco finish? Brick finish? 2) Any size preferences, how many stalls need to be included or just small with one men's and one women's restrooms? 3) What is the requested size on the storage sheds, are these precast concrete?

Response: Q1. For the precast concrete restrooms and dugouts are there preferences for the exterior appearance? Smooth stucco finish? Brick finish? Answer: No, this depends on the project. Q2. Any size preferences, how many stalls need to be included or just small with one men's and one women's restrooms? Answer: Unless otherwise specified, restroom stalls shall be unisex and ADA-compliant, with room for changing tables. Q3. What is the requested size on the storage sheds, are these precast concrete? Answer: There is no requested size. The size of the storage sheds will vary from project to project. They may be precast concrete, although other materials may be acceptable.